How to Pass VMware Certified Master Specialist 5V0-21.21 Exam, We know that it will be very difficult for you to choose the suitable 5V0-21.21 learning guide, If you buy our 5V0-21.21 torrent vce, we promise that you only need twenty to thirty hours practice to pass the VMware HCI Master Specialist online test engine and get the VMware Certified Master Specialist certificate, VMware 5V0-21.21 Test Simulator Efficient way to succeed.

During the acquisition phase, content is gathered from various Braindump 5V0-21.21 Free sources such as cameras i.e, Human beings, regardless of culture or language, have a universal language.

Download 5V0-21.21 Exam Dumps

You can just slide your finger toward the edge and then https://www.testkingpass.com/vmware-hci-master-specialist-testking-12868.html get tactile feedback that it's time to stop, Personalizing the Lock Screen, Replay protection mode: Strict.

How to Pass VMware Certified Master Specialist 5V0-21.21 Exam, We know that it will be very difficult for you to choose the suitable 5V0-21.21 learning guide, If you buy our 5V0-21.21 torrent vce, we promise that you only need twenty https://www.testkingpass.com/vmware-hci-master-specialist-testking-12868.html to thirty hours practice to pass the VMware HCI Master Specialist online test engine and get the VMware Certified Master Specialist certificate.

Efficient way to succeed, You can totally believe 5V0-21.21 Reliable Study Plan us and choose us, In fact, there is no point in wasting much time on invalid input, The industry experts hired by 5V0-21.21 exam materials are those who have been engaged in the research of 5V0-21.21 exam for many years.

Free PDF Quiz 5V0-21.21 - High Pass-Rate VMware HCI Master Specialist Test Simulator

5V0-21.21 training vce pdf has many years of experience and our experts have been devoted themselves to the study of 5V0-21.21 certification exam and summarize exam rules.

Knowledge is the most precious asset of a person, They will acquire more access to work abroad for further studies, By our professional training, you will pass your 5V0-21.21 exam and get the related certification in the shortest time.

Do you have that idea?

Download VMware HCI Master Specialist Exam Dumps

NEW QUESTION 25
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?

A. Obtain additional free capacity from the existing NAS storage.B. Obtain additional free capacity from the existing FC storage.C. Create an HCI Mesh using the second cluster's datastore.D. Create an HCI Mesh using the first cluster's datastore.

Answer: C

Explanation:
https://blogs.vmware.com/virtualblocks/2020/09/16/introducing-vmware-vsan-hci-mesh/

 

NEW QUESTION 26
A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?

A. All objects will remain accessible.B. A rebuild of the affected objects will occur.C. The cluster will be partitioned and the vSAN host will need to be rejoined.D. All objects on the affected host will be lost.

Answer: B

 

NEW QUESTION 27
multiple data centers, the customer relayed the following information:
* Highest possible mitigation during a host failure in terms of capacity.
* A constraint in this year's IT budget.
What should the architect recommend?

A. Enable operations reserve.
A minimum cluster of 3 vSAN nodes.B. Enable host build reserve.
A minimum cluster of 4 vSAN nodes.C. Enable performance services.
A minimum cluster of 6 vSAN nodes.D. Enable IOInsight Metrics.
A minimum cluster of 2 vSAN ROBO nodes.

Answer: B

Explanation:
Performance services and IOinsight Metrics used for performance analysis. Operation reserve for internal VSAN operations. https://blogs.vmware.com/virtualblocks/2020/09/24/effective-capacity-management-with-vsan-7-update-1/

 

NEW QUESTION 28
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1.
During the discovery phase, the consultant found the following information about the existing environment:
* The VMware vCenter Server has recently been upgraded from VMware vSphere 6.7 U3 to version 7.0 U1.
* The vSAN Cluster was recently expanded with identical hardware specification, but from a different hardware vendor.
* The hardware for each vSAN node is listed on the vSAN Compatibility Guide (VCG) for vSAN 7.
* The vSAN Cluster has the following configuration:
- vSAN version: 6.6.1
- Number of vSAN nodes: 10
- Encryption: enabled
- Deduplication and Compression: enabled
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- VMware vSphere ESXi version: 6.5 Update 3
- CPU: 2 processors, 20 cores
- RAM: 768GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
Which three recommendations should the consultant make to ensure all data remains protected in the event of a vSAN failure? (Choose three.)

A. The Ensure accessibility, migration maintenance mode option must be chosen to protect the data during the upgrade.B. The vSAN nodes should be upgraded to vSphere ESXi 6.7 U3.C. The upgrade process should be completed using images in VMware vSphere Lifecycle Manager (vLCM).D. The upgrade process should be completed using host upgrade baselines in VMware vSphere Lifecycle Manager (vLCM).E. The vSAN nodes should be upgraded to vSphere ESXi 7.0 U1.F. The Full data migration maintenance mode option must be chosen to protect the data during the upgrade.

Answer: D,E,F

Explanation:
https://blogs.vmware.com/virtualblocks/2018/10/29/a-closer-look-at-emm/

 

NEW QUESTION 29
An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.
The following information is known about the vSAN Cluster:
* vSAN 7.x Cluster
* vSAN node count: 8
* De-Duplication and Compression: Enabled.
* Encryption: Disabled
* Current Utilization: 45%
* Disk Groups: 2
* Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD
Which three steps should the administrator take to successfully complete the task? (Choose three.)

A. Remove the affected Disk from the Disk Group, and choose Full Data Migration.B. Put the affected vSAN host into maintenance mode to physically replace the storage device.C. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.D. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.E. Replace the failed disk with a storage device that is identical in class but smaller in capacity.F. Replace the failed disk with a storage device that is identical in class and capacity.

Answer: A,B,F

Explanation:
If you upgrade the capacity device, verify the following requirements:
- Verify that the cluster contains enough space to migrate the data from the capacity device.
- Place the host in maintenance mode. See Place a Member of Virtual SAN Cluster in Maintenance Mode.
"Select the flash capacity device or magnetic disk, and click Remove selected disk(s) from disk group."
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.virtualsan.doc/GUID-4E3390C1-6C50-49E5-AEB6-C9BC037979A1.html

 

NEW QUESTION 30
......


>>https://www.testkingpass.com/5V0-21.21-testking-dumps.html