What's more, part of that PassLeaderVCE 3V0-22.21 dumps now are free: https://drive.google.com/open?id=1fpszAwjC3i-zB25jPXBxWi-oHUxUX8s4
We continually improve the versions of our 3V0-22.21 exam guide so as to make them suit all learners with different learning levels and conditions. The clients can use the APP/Online test engine of our 3V0-22.21 exam guide in any electronic equipment such as the cellphones, laptops and tablet computers. Our after-sale service is very considerate and the clients can consult our online customer service about the price and functions of our 3V0-22.21 Quiz materials. So our 3V0-22.21 certification files are approximate to be perfect and will be a big pleasant surprise after the clients use them.
If you are preparing for the 3V0-22.21 questions and answers, and like to practice it in your spare time, then you should conseder the 3V0-22.21 exam dumps of our company. 3V0-22.21 Online test engine is convenient and easy to study, it supports all web browsers. Besides you can practice online anytime. With all the benefits like this, you can choose us bravely. With this version, you can pass the exam easily, and you don’t need to spend the specific time for practicing, just your free time is ok.
3V0-22.21 Reliable Dumps | 3V0-22.21 Free Test QuestionsThe clients can consult our online customer service before and after they buy our Advanced Deploy VMware vSphere 7.x Exam guide dump. We provide considerate customer service to the clients. Before the clients buy our 3V0-22.21 cram training materials they can consult our online customer service personnel about the products’ version and price and then decide whether to buy them or not. After the clients buy the 3V0-22.21 study tool they can consult our online customer service about how to use them and the problems which occur during the process of using. If the clients fail in the test and require the refund our online customer service will reply their requests quickly and deal with the refund procedures promptly. In short, our online customer service will reply all of the clients’ questions about the 3V0-22.21 cram training materials timely and efficiently.
VMware 3V0-22.21 Exam Syllabus Topics:TopicDetailsTopic 1Configure and manage VMware vCenter Server® backup and restore options Set up log collection and VMware vCenter Server® backupTopic 2Configure and manage High Availability options Set up a clustering solution for VMware vSphere® High Availability (HA)Topic 3Deploy and manage VMware vSphere® Distributed Switch (VDS) Deploy and manage VMware vSphere® Standard Switch (vSS)Topic 4Create and manage host profiles (e.g. edit and apply host profiles) Implement VMware vSphere® virtual machine encryption (VM encryption)Topic 5Deploy and configure VMware vCenter Server® and VMware ESXi™ Set up a cluster solution for VMware vSphere® Distributed Resource Scheduler™ (DRS)Topic 6Identify and implement vSphere® resource optimization opportunities Performance-tuning, Optimization, and UpgradesVMware Advanced Deploy VMware vSphere 7.x Exam Sample Questions (Q14-Q19):
NEW QUESTION # 14
Your security team is getting ready for an audit and wants to check the status of all ESXI hosts' outstanding security patches. Create a new fixed Update Manager baseline for all security ESXi host patches and name it ''Security patches. ''Use the patches available in the patch repository. Use VCSA01a in this task.
Baseline Name: Security Patches
Baseline Type: Host Patch
Category: Security
Answer:
Explanation:
The Update Manager displays system managed baselines that are generated by vSAN. These baselines appear by default when you use vSAN clusters with ESXi hosts of version 6.0 Update 2 and later in your vSphere inventory. If your vSphere environment does not contain any vSAN clusters, no system managed baselines are created.
The system managed baselines automatically update their content periodically, which requires Update Manager to have constant access to the Internet. The vSAN system baselines are typically refreshed every 24 hours.
You use system managed baselines to upgrade your vSAN clusters to recommended critical patches, drivers, updates or the latest supported ESXi host version for vSAN.
System managed baselines cannot be edited or deleted. You do not attach system managed baselines to inventory objects in your vSphere environment. You can create a baseline group of multiple system managed baselines, but you cannot add any other type of basline to that group. Similarly, you cannot add a system managed baseline to a baseline group that contains upgrade, patch, and extension baselines.
NEW QUESTION # 15
A vSphere administrator has deployed a new server. The VM will have a workload which is prodApp1 to the following specifications:
* The VM should never have any memory contention while powered on. even if the host that it resides
* Configure the virtual machine for high latency sensitivity.
Answer: A
NEW QUESTION # 16
The company's IT strategy is to adopt innovative and emerging technologies such as software-defined storage solution. The IT team has decided to run their business-critical workloads on an all-flash Virtual SAN (vSAN) as it provides excellent performance.
The IT team has purchased servers that are compatible with vSAN. However, all the solid-state drives (SSD) in the servers are shown incorrectly as hard-disk drives (HDD) instead.
In addition, some of the solid-state drives (SSD) will be used for other purposes instead of vSAN and should not be part of the vSAN cluster. These are the requirements for the vSAN cluster:
* In each server, use the 3GB SSD as the cache tier and the 11GB SSD as the capacity tier
* As a result the vSAN cluster will use a total of six SSDs (three SSDs for caching and three SSDs for capacity
* Ensure all the disks that will be used for vSAN are shown correctly as SSDs
* Provide storage savings by using deduplication and compression.
Next, the IT team wants to improve the performance and availability of the business-critical workloads on the vSAN-datastore.
Ensure the following configurations will be applied on existing and new workloads located on vSAN-datastore:
Number of disk stripes per object: 2
Primary level of failures to tolerate: 2
Failure tolerance method: RAID-1 (Mirroring)
Force provisioning; Yes
The new configurations should be applied by default.
You may create new storage policy but do not edit the default vSAN storage policy as it may be used by other vSAN clusters in the future. Name the policy "New vSAN Default'.
Note: All tasks should be executed in PROD-A host cluster.
Answer:
Explanation:
VMware vSphere ESXi can use locally attached SSDs (Solid State Disk) and flash devices in multiple ways. Since SSDs offer much higher throughput and much lower latency than traditional magnetic hard disks the benefits are clear. While offering lower throughput and higher latency, flash devices such as USB or SATADOM can also be appropriate for some use cases. The potential drawback to using SSDs and flash device storage is that the endurance can be significantly less than traditional magnetic disks and it can vary based on the workload type as well as factors such as the drive capacity, underlying flash technology, etc.
This KB outlines the minimum SSD and flash device recommendations based on different technologies and use case scenarios.
SSD and Flash Device Use Cases
A non-exhaustive survey of various usage models in vSphere environment are listed below.
Host swap cache
This usage model has been supported since vSphere 5.1 for SATA and SCSI connected SSDs. USB and low end SATA or SCSI flash devices are not supported.
The workload is heavily influenced by the degree of host memory over commitment.
Regular datastore
A (local) SSD is used instead of a hard disk drive.
This usage model has been supported since vSphere 7.0 for SATA and SCSI connected SSDs.
There is currently no support for USB connected SSDs or for low end flash devices regardless of connection type.
vSphere Flash Read Cache (aka Virtual Flash)
This usage model has been supported since vSphere 5.5 for SATA and SCSI connected SSDs.
There is no support for USB connected SSDs or for low end flash devices.
vSAN
This usage model has been supported since vSphere 5.5 for SATA and SCSI SSDs. For more information, see the vSAN Hardware Quick Reference Guide.
vSphere ESXi Boot Disk
A USB flash drive or SATADOM or local SSD can be chosen as the install image for ESXi, the vSphere hypervisor, which then boots from the flash device.
This usage model has been supported since vSphere 3.5 for USB flash devices and vSphere 4.0 for SCSI/SATA connected devices.
Installation to SATA and SCSI connected SSD, SATADOM and flash devices creates a full install image which includes a logging partition (see below) whereas installation to a USB device creates a boot disk image without a logging partition.
vSphere ESXi Coredump device
The default size for the coredump partition is 2.5 GiB which is about 2.7 GB and the installer creates a coredump partition on the boot device device for vSphere 5.5 and above. After installation the partition can be resized if necessary using partedUtil. For more information, see the vSphere documentation.
Any SATADOM or SATA/SCSI SSD may be configured with a coredump partition.
This usage model has been supported from vSphere 3.5 for boot USB flash devices and since vSphere 4.0 for any SATA or SCSI connected SSD that is local.
This usage model also applies to Autodeploy hosts which have no boot disk.
vSphere ESXi Logging device
A SATADOM or local SATA/SCSI SSD is chosen as the location for the vSphere logging partition (/scratch partition). This partition may be but need not be on the boot disk and this applies to Autodeploy hosts which lack a boot disk.
This usage model has been supported since vSphere 7.0 for any SATA or SCSI connected SSD that is local. SATADOMs that meet the requirement set forth in Table 1 are also supported.
This usage model can be supported in a future release of vSphere for USB flash devices that meet the requirement set forth in Table 1.
SSD Endurance Criteria
The flash industry often uses Tera Bytes Written (TBW) as a benchmark for SSD endurance. TBW is the number of terabytes that can be written to the device over its useful life. Most devices have distinct TBW ratings for sequential and random IO workloads, with the latter being much lower due to Write Amplification Factor (WAF) (defined below). Other measures of endurance commonly used are DWPD (Drive Writes Per Day) and P/E (Program/Erase) cycles.
Conversion formulas are provided here:
Converting DWPD (Drive Writes Per Day) to TBW (Terabytes Written):
TBW = DWPD * Warranty (in Years) * 365 * Capacity (in GB) / 1,000 (GB per TB) Converting Flash P/E Cycles per Cell to TBW (Terabytes Written):
TBW = Capacity (in GB) * (P/E Cycles per Cell) / (1,000 (GB per TB) * WAF) WAF is a measure of the induced writes caused by inherent properties of flash technology. Due to the difference between the storage block size (512 bytes), the flash cell size (typically 4KiB or 8KiB bytes) and the minimum flash erase size of many cells one write can force a number of induced writes due to copies, garbage collection, etc. For sequential workloads typical WAFs fall in the range of single digits while for random workloads WAFs can approach or even exceed 100. Table 1 contains workload characterization for the various workloads excepting the Datastore and vSphere Flash Read Cache workloads which depend on the characteristics of the Virtual Machines workloads being run and thus cannot be characterized here. A WAF from the table can be used with the above P/E to TBW formula.
NEW QUESTION # 17
You have just deployed a new vCenter Server Appliance. Vcsa0l
a. and are required to back up to configuration after deployment. To complete this task, perform an unencrypted backup of the vCenter Server Appliance using the following details:
* Use the FTP protocol to backup the appliance
* FTP Server Location: 172.20.10.10/
* FTP Username: administrator
* FTP Password: VMware1!
Note: Make sure you include the / at the end of the Server Location
Answer:
Explanation:
Prerequisites
You must have an FTP, FTPS, HTTP, HTTPS, or SCP server up and running with sufficient disk space to store the backup.
Dedicate a separate folder on your server for each file-based backup.
Procedure
In a Web browser, go to the vCenter Server Appliance Management Interface, https://appliance-IP-address-or-FQDN:5480.
Log in as root.
In the vCenter Server Appliance Management Interface, click Summary.
Click Backup.
The Backup Appliance wizard opens.
Enter the backup protocol and location details.
Option
Description
Backup protocol
Select the protocol to use to connect to your backup server. You can select FTP, FTPS, HTTP, HTTPS, or SCP.
For FTP, FTPS, HTTP, or HTTPS the path is relative to the home directory configured for the service. For SCP, the path is absolute to the remote systems root directory.
Backup location
Enter the server address and backup folder in which to store the backup files.
Port
Enter the default or custom port of the backup server.
User name
Enter a user name of a user with write privileges on the backup server.
Password
Enter the password of the user with write privileges on the backup server.
(Optional) Select Encrypt Backup Data to encrypt your backup file and enter a password for the encryption.
If you select to encrypt the backup data, you must use the encryption password for the restore procedure.
Click Next.
On the Select parts to backup page, review the data that is backed up by default.
(Optional) Select Stats, Events, and Tasks to back up additional historical data from the database.
(Optional) In the Description text box, enter a description of the backup and click Next.
On the Ready to complete page, review the summary information for the backup and click Finish.
The Backup Progress window opens and indicates the progress of the backup operation.
After the backup process finishes, click OK to close the Backup Progress window.
Results
You successfully created a backup file of the vCenter Server Appliance.
NEW QUESTION # 18
The Virtual Infrastructure team wants to share a VM Template from vcsa0la to vcsa0lb via content libraries. Ensure that the content in the libraries is synchronized only when needed.
* Name of Published Content Library in vcsa0la: CL01
* Name of Subscribed Content Library in vcsa0lb: CL02
* For both content libraries, use the local datastore: SAN01
* VM Template to be shared: Core-Template
After the Core-Template has been synchronized from CL01 to CL02. deploy a virtual machine from VM-Template on vcsa0lb
* Name of virtual machine: CL-VM
* Host for virtual machine: sxi03b
Answer: A
NEW QUESTION # 19
......
Our study material is not same as other dumps or study tools, it not only has good quality but also has cheap price. We have most professional team to compiled and revise 3V0-22.21 exam question, in order to try our best to help you pass the exam and get a better condition of your life and your work. Moreover, only need to spend 20-30 is it enough for you to grasp whole content of 3V0-22.21 practice materials that you can pass the exam easily, this is simply unimaginable.
3V0-22.21 Reliable Dumps: https://www.passleadervce.com/VMware-Certified-Advanced-Professional/reliable-3V0-22.21-exam-learning-guide.html
2023 Latest PassLeaderVCE 3V0-22.21 PDF Dumps and 3V0-22.21 Exam Engine Free Share: https://drive.google.com/open?id=1fpszAwjC3i-zB25jPXBxWi-oHUxUX8s4